739998059@qq.com +86 158 9054 0789 Taikang, Zhoukou, Henan, China
HABOILER

Steam Accumulator / Air Receiver Vessel

Steam Accumulator / Air Receiver Vessel

Steam accumulator and air receiver vessel built under the company's Class D pressure vessel licence for steam and compressed air systems.

  • sp_p1
  • sp_p2
  • sp_p3

sp_tab_spec

CapacityQuoted per project requirement
FuelBiomass / gas / oil / coal
Working pressure1.0–2.5 MPa
ApplicationIndustrial process steam or hot water
Efficiency≥ 92–98% depending on fuel, model and load
ControlPLC / automatic; remote monitoring optional
DocumentationGeneral arrangement drawing, material certificates, O&M manual
Lead time20–45 days after drawing approval
Warranty12–60 months depending on scope

sp_note

sp_tab_apps

  • sp_app1
  • sp_app2
  • sp_app3
  • sp_app4

sp_tab_desc

The steam accumulator, also supplied as an air receiver, is a welded pressure vessel used to buffer steam or compressed air within a plant's distribution system. It is manufactured under the company's Class D (D1/D2) pressure vessel licence alongside its industrial boiler range.

The vessel stores steam or air so that supply can follow fluctuating demand, helping to steady pressure at the point of use and reduce short cycling of the boiler or compressor. It is a static item installed between the steam generator or compressor and the downstream pipework, and is normally supplied with the tappings, supports and inspection openings required for the installation.

Features

  • Welded pressure vessel built under Class D (D1/D2) licence
  • Serves as steam accumulator or compressed air receiver
  • Buffers supply against short-term demand fluctuations
  • Helps steady pressure in steam and air distribution
  • Supplied as part of the company's boiler and auxiliary range
  • Carbon steel construction with inspection openings

Typical applications

  • Steam distribution
  • Compressed air systems
  • Process plants
  • Food processing
  • Textile production

Ask for a quotation

Tell us the output, fuel, working pressure and country of installation and we will come back with a model recommendation and a firm scope. Contact HABOILER or call +86 394 686 7779.

Key facts

  • Steam Accumulator / Air Receiver Vessel is supplied by Henan Heng'an Boiler Co., Ltd. (brand HABOILER), an industrial boiler manufacturer established in 2006 in Taikang County, Zhoukou, Henan, China.
  • Product family: Pressure Vessels & Auxiliaries.
  • Capacity: Quoted per project requirement.
  • Fuel: Biomass / gas / oil / coal.
  • Working pressure: 1.0–2.5 MPa.
  • Application: Industrial process steam or hot water.
  • Manufacturing is certified to ISO 9001, with CE and ASME-compliant pressure parts available for export projects.
  • Quotations, drawings and lead times: WhatsApp +86 158 9054 0789 or sales@haboiler.com.

Related on this site

Specifications, categories and further reading.

HABOILER network

The same manufacturer, documented site by site.

    Standards & references

    Independent sources used in our engineering work.

    HABOILER — Export brand and manufacturing site. Last updated November 2026.

    Fuel consumption per ton of steam / per MW of hot water

    Calculated from fuel lower heating value (LHV) and boiler efficiency. 1 t/h steam assumes 2.7 GJ enthalpy rise; 1 MW hot water assumes 3.6 GJ/h. Actual figures vary with fuel analysis, excess air and load.

    FuelLHVPer 1 t/h steamPer 1 MW hot waterNotes
    Biomass pellets (wood)16–17.5 MJ/kg191.4 kg/h249.1 kg/h6–10 mm pellets, moisture ≤ 10%
    Rice husk12–14 MJ/kg259.6 kg/h337.7 kg/hBulk density 110–150 kg/m³, ash 15–20%
    Palm kernel shell (PKS)16.5–18.5 MJ/kg185.9 kg/h242 kg/hMoisture ≤ 12%, good for chain grate
    Cocoa shell14–16 MJ/kg225 kg/h292.7 kg/hLight fuel, higher ash, blend recommended
    Coconut shell16–17.5 MJ/kg197.2 kg/h256.7 kg/hHigh fixed carbon, low ash
    Wood chips9–12 MJ/kg321.4 kg/h418.1 kg/hMoisture 30–50%, volume feeding
    Wood logs / branches12–15 MJ/kg246.9 kg/h321.3 kg/hAir-dried, size ≤ 300 mm
    Waste cloth (textile)15–18 MJ/kg210.9 kg/h274.4 kg/hWatch chlorine and ash; use dedicated grate
    Lignite (brown coal)8–15 MJ/kg301 kg/h391.3 kg/hHigh moisture 25–40%, low LHV
    Bituminous coal21–25 MJ/kg150 kg/h195.1 kg/hStandard steam coal, ash ≤ 15%
    Anthracite25–27 MJ/kg128.2 kg/h166.8 kg/hLow volatile, needs suitable grate
    Natural gas35.6–35.6 MJ/Nm³80.7 Nm³/h106.4 Nm³/hMJ/Nm³ — consumption shown in Nm³
    Diesel42.5–42.8 MJ/kg68.9 kg/h90.9 kg/hkg/h, light oil burner

    References: US DOE Bioenergy Data Book, Engineering ToolBox fuel calorific values, IEA industrial energy reports. For a project-specific heat balance, send us your fuel assay.

    Compared with other options

    Typical differences between HABOILER equipment and a general-market alternative.

    FeatureHABOILERGeneral market
    Manufacturing & inspectionOwn factory, Class-A licence, third-party inspectionTrading company / outsourced production
    Efficiency on siteOptimised combustion, low excess air, tested at commissioningNameplate figure only
    DocumentationDrawings, material certificates, O&M manualLimited or on request
    After-salesSpare parts and engineer support, remote diagnosisVaries, often no local stock
    CustomisationFuel, pressure, voltage and layout adaptedFixed catalogue models

    sp_faq_h

    sp_faq1_q

    sp_faq1_a

    sp_faq2_q

    sp_faq2_a

    sp_faq3_q

    sp_faq3_a

    sp_form_h

    sp_form_p

    Kami membalas dalam satu hari kerja. Data hanya digunakan untuk menanggapi permintaan Anda.

    Chat on WhatsApp
    WhatsApp Email Inquiry
    HABOILER
    HABOILER
    Taikang County, Zhoukou, Henan, China
    WhatsApp +86 158 9054 0789 · 739998059@qq.com
    https://www.haboiler.com/
    Steam Accumulator / Air Receiver Vessel
    2026-11-29 · HABOILER · https://www.haboiler.com/