sp_tab_spec
| Capacity | Quoted per project requirement |
|---|---|
| Fuel | Biomass / gas / oil / coal |
| Working pressure | 1.0–2.5 MPa |
| Application | Industrial process steam or hot water |
| Efficiency | ≥ 92–98% depending on fuel, model and load |
| Control | PLC / automatic; remote monitoring optional |
| Documentation | General arrangement drawing, material certificates, O&M manual |
| Lead time | 20–45 days after drawing approval |
| Warranty | 12–60 months depending on scope |
sp_note
sp_tab_apps
- sp_app1
- sp_app2
- sp_app3
- sp_app4
sp_tab_desc
The autoclave is a horizontal pressure vessel used for steam curing of aerated concrete (AAC) blocks and other cementitious products. It is manufactured by HABOILER, whose Class D (D1/D2) pressure vessel licence covers this type of equipment.
Units are installed in AAC block plants and precast concrete works, where saturated steam under pressure accelerates curing and helps develop the final strength of the product. The company also builds curing kettles as part of the same pressure-vessel range.
Features
- Horizontal pressure vessel for saturated steam curing
- Suitable for AAC block and curing kettle duty
- Built under Class D (D1/D2) pressure vessel licence
- Part of HABOILER's pressure-vessel product range
- Designed for integration with AAC production lines
Typical applications
- AAC block plants
- Concrete curing
- Building materials
- Precast components
Ask for a quotation
Tell us the output, fuel, working pressure and country of installation and we will come back with a model recommendation and a firm scope. Contact HABOILER or call +86 394 686 7779.
Key facts
- AAC Block Autoclave is supplied by Henan Heng'an Boiler Co., Ltd. (brand HABOILER), an industrial boiler manufacturer established in 2006 in Taikang County, Zhoukou, Henan, China.
- Product family: Pressure Vessels & Auxiliaries.
- Capacity: Quoted per project requirement.
- Fuel: Biomass / gas / oil / coal.
- Working pressure: 1.0–2.5 MPa.
- Application: Industrial process steam or hot water.
- Manufacturing is certified to ISO 9001, with CE and ASME-compliant pressure parts available for export projects.
- Quotations, drawings and lead times: WhatsApp +86 158 9054 0789 or sales@haboiler.com.
Related on this site
Specifications, categories and further reading.
- All Pressure Vessels & AuxiliariesBrowse the complete Pressure Vessels & Auxiliaries range.
- Boiler BurnerRelated Pressure Vessels & Auxiliaries model with full specifications.
- Boiler Circulation PumpRelated Pressure Vessels & Auxiliaries model with full specifications.
- Boiler EconomiserRelated Pressure Vessels & Auxiliaries model with full specifications.
- Steam Header (Distributing Cylinder)Related Pressure Vessels & Auxiliaries model with full specifications.
- Boiler Induced Draught FanRelated Pressure Vessels & Auxiliaries model with full specifications.
- Steam Sterilisation VesselRelated Pressure Vessels & Auxiliaries model with full specifications.
- Complete product rangeEvery boiler, heater, pressure vessel and autoclave we manufacture.
HABOILER network
The same manufacturer, documented site by site.
Standards & references
Independent sources used in our engineering work.
- ASME Boiler and Pressure Vessel CodeThe international reference code for boiler and pressure-vessel design and fabrication.
- ISO 9001 quality managementThe quality-management standard our manufacturing system is certified against.
- Spirax Sarco — learn about steamIndependent engineering reference for steam, condensate and heat-transfer practice.
- Boiler — WikipediaBackground on boiler types, fuels and thermodynamic principles.
- U.S. DOE — industrial steam systemsReference material on industrial steam-system efficiency.
HABOILER — Export brand and manufacturing site. Last updated November 2026.
This model is covered by the autoclaves, steam storage and pressure vessels manual: site requirements, commissioning checks, and the daily, monthly and annual maintenance schedules.
Fuel consumption per ton of steam / per MW of hot water
Calculated from fuel lower heating value (LHV) and boiler efficiency. 1 t/h steam assumes 2.7 GJ enthalpy rise; 1 MW hot water assumes 3.6 GJ/h. Actual figures vary with fuel analysis, excess air and load.
| Fuel | LHV | Per 1 t/h steam | Per 1 MW hot water | Notes |
|---|---|---|---|---|
| Biomass pellets (wood) | 16–17.5 MJ/kg | 191.4 kg/h | 249.1 kg/h | 6–10 mm pellets, moisture ≤ 10% |
| Rice husk | 12–14 MJ/kg | 259.6 kg/h | 337.7 kg/h | Bulk density 110–150 kg/m³, ash 15–20% |
| Palm kernel shell (PKS) | 16.5–18.5 MJ/kg | 185.9 kg/h | 242 kg/h | Moisture ≤ 12%, good for chain grate |
| Cocoa shell | 14–16 MJ/kg | 225 kg/h | 292.7 kg/h | Light fuel, higher ash, blend recommended |
| Coconut shell | 16–17.5 MJ/kg | 197.2 kg/h | 256.7 kg/h | High fixed carbon, low ash |
| Wood chips | 9–12 MJ/kg | 321.4 kg/h | 418.1 kg/h | Moisture 30–50%, volume feeding |
| Wood logs / branches | 12–15 MJ/kg | 246.9 kg/h | 321.3 kg/h | Air-dried, size ≤ 300 mm |
| Waste cloth (textile) | 15–18 MJ/kg | 210.9 kg/h | 274.4 kg/h | Watch chlorine and ash; use dedicated grate |
| Lignite (brown coal) | 8–15 MJ/kg | 301 kg/h | 391.3 kg/h | High moisture 25–40%, low LHV |
| Bituminous coal | 21–25 MJ/kg | 150 kg/h | 195.1 kg/h | Standard steam coal, ash ≤ 15% |
| Anthracite | 25–27 MJ/kg | 128.2 kg/h | 166.8 kg/h | Low volatile, needs suitable grate |
| Natural gas | 35.6–35.6 MJ/Nm³ | 80.7 Nm³/h | 106.4 Nm³/h | MJ/Nm³ — consumption shown in Nm³ |
| Diesel | 42.5–42.8 MJ/kg | 68.9 kg/h | 90.9 kg/h | kg/h, light oil burner |
References: US DOE Bioenergy Data Book, Engineering ToolBox fuel calorific values, IEA industrial energy reports. For a project-specific heat balance, send us your fuel assay.
Compared with other options
Typical differences between HABOILER equipment and a general-market alternative.
| Feature | HABOILER | General market |
|---|---|---|
| Manufacturing & inspection | Own factory, Class-A licence, third-party inspection | Trading company / outsourced production |
| Efficiency on site | Optimised combustion, low excess air, tested at commissioning | Nameplate figure only |
| Documentation | Drawings, material certificates, O&M manual | Limited or on request |
| After-sales | Spare parts and engineer support, remote diagnosis | Varies, often no local stock |
| Customisation | Fuel, pressure, voltage and layout adapted | Fixed catalogue models |
Further reading
sp_faq_h
sp_faq1_q
sp_faq1_a
sp_faq2_q
sp_faq2_a
sp_faq3_q
sp_faq3_a
sp_form_h
sp_form_p