sp_tab_spec
| Capacity | Quoted per project requirement |
|---|---|
| Fuel | Biomass / gas / oil / coal |
| Working pressure | 1.0–2.5 MPa |
| Application | Industrial process steam or hot water |
| Efficiency | ≥ 92–98% depending on fuel, model and load |
| Control | PLC / automatic; remote monitoring optional |
| Documentation | General arrangement drawing, material certificates, O&M manual |
| Lead time | 20–45 days after drawing approval |
| Warranty | 12–60 months depending on scope |
sp_note
sp_tab_apps
- sp_app1
- sp_app2
- sp_app3
- sp_app4
sp_tab_desc
The boiler economiser is a heat recovery unit installed in the flue gas path of an industrial boiler. It transfers residual heat from the exhaust gas to the boiler feedwater, reducing the heat otherwise lost through the stack.
It is used in steam and hot water boiler systems across process industries, where continuous operation makes flue gas heat recovery practical. The unit forms part of the company's pressure vessel and boiler auxiliary range.
Features
- Recovers residual heat from boiler flue gas
- Reduces flue gas temperature before the stack
- Transfers heat to boiler feedwater
- Improves overall thermal performance of the system
- Built as a pressure vessel component
- Suitable for steam and hot water boilers
Typical applications
- Power generation
- Chemical processing
- Food and beverage
- Textile production
- Pulp and paper
Ask for a quotation
Tell us the output, fuel, working pressure and country of installation and we will come back with a model recommendation and a firm scope. Contact HABOILER or call +86 394 686 7779.
Key facts
- Boiler Economiser is supplied by Henan Heng'an Boiler Co., Ltd. (brand HABOILER), an industrial boiler manufacturer established in 2006 in Taikang County, Zhoukou, Henan, China.
- Product family: Pressure Vessels & Auxiliaries.
- Capacity: Quoted per project requirement.
- Fuel: Biomass / gas / oil / coal.
- Working pressure: 1.0–2.5 MPa.
- Application: Industrial process steam or hot water.
- Manufacturing is certified to ISO 9001, with CE and ASME-compliant pressure parts available for export projects.
- Quotations, drawings and lead times: WhatsApp +86 158 9054 0789 or sales@haboiler.com.
Related on this site
Specifications, categories and further reading.
- All Pressure Vessels & AuxiliariesBrowse the complete Pressure Vessels & Auxiliaries range.
- Boiler Circulation PumpRelated Pressure Vessels & Auxiliaries model with full specifications.
- Boiler Induced Draught FanRelated Pressure Vessels & Auxiliaries model with full specifications.
- AAC Block AutoclaveRelated Pressure Vessels & Auxiliaries model with full specifications.
- Wood Pressure Impregnation VesselRelated Pressure Vessels & Auxiliaries model with full specifications.
- Boiler BurnerRelated Pressure Vessels & Auxiliaries model with full specifications.
- Steam Sterilisation VesselRelated Pressure Vessels & Auxiliaries model with full specifications.
- Complete product rangeEvery boiler, heater, pressure vessel and autoclave we manufacture.
Standards & references
Independent sources used in our engineering work.
- ASME Boiler and Pressure Vessel CodeThe international reference code for boiler and pressure-vessel design and fabrication.
- ISO 9001 quality managementThe quality-management standard our manufacturing system is certified against.
- Spirax Sarco — learn about steamIndependent engineering reference for steam, condensate and heat-transfer practice.
- Boiler — WikipediaBackground on boiler types, fuels and thermodynamic principles.
- U.S. DOE — industrial steam systemsReference material on industrial steam-system efficiency.
HABOILER — Export brand and manufacturing site. Last updated November 2026.
This model is covered by the WNS / CWNS fire-tube oil & gas boilers manual: site requirements, commissioning checks, and the daily, monthly and annual maintenance schedules.
Fuel consumption per ton of steam / per MW of hot water
Calculated from fuel lower heating value (LHV) and boiler efficiency. 1 t/h steam assumes 2.7 GJ enthalpy rise; 1 MW hot water assumes 3.6 GJ/h. Actual figures vary with fuel analysis, excess air and load.
| Fuel | LHV | Per 1 t/h steam | Per 1 MW hot water | Notes |
|---|---|---|---|---|
| Biomass pellets (wood) | 16–17.5 MJ/kg | 191.4 kg/h | 249.1 kg/h | 6–10 mm pellets, moisture ≤ 10% |
| Rice husk | 12–14 MJ/kg | 259.6 kg/h | 337.7 kg/h | Bulk density 110–150 kg/m³, ash 15–20% |
| Palm kernel shell (PKS) | 16.5–18.5 MJ/kg | 185.9 kg/h | 242 kg/h | Moisture ≤ 12%, good for chain grate |
| Cocoa shell | 14–16 MJ/kg | 225 kg/h | 292.7 kg/h | Light fuel, higher ash, blend recommended |
| Coconut shell | 16–17.5 MJ/kg | 197.2 kg/h | 256.7 kg/h | High fixed carbon, low ash |
| Wood chips | 9–12 MJ/kg | 321.4 kg/h | 418.1 kg/h | Moisture 30–50%, volume feeding |
| Wood logs / branches | 12–15 MJ/kg | 246.9 kg/h | 321.3 kg/h | Air-dried, size ≤ 300 mm |
| Waste cloth (textile) | 15–18 MJ/kg | 210.9 kg/h | 274.4 kg/h | Watch chlorine and ash; use dedicated grate |
| Lignite (brown coal) | 8–15 MJ/kg | 301 kg/h | 391.3 kg/h | High moisture 25–40%, low LHV |
| Bituminous coal | 21–25 MJ/kg | 150 kg/h | 195.1 kg/h | Standard steam coal, ash ≤ 15% |
| Anthracite | 25–27 MJ/kg | 128.2 kg/h | 166.8 kg/h | Low volatile, needs suitable grate |
| Natural gas | 35.6–35.6 MJ/Nm³ | 80.7 Nm³/h | 106.4 Nm³/h | MJ/Nm³ — consumption shown in Nm³ |
| Diesel | 42.5–42.8 MJ/kg | 68.9 kg/h | 90.9 kg/h | kg/h, light oil burner |
References: US DOE Bioenergy Data Book, Engineering ToolBox fuel calorific values, IEA industrial energy reports. For a project-specific heat balance, send us your fuel assay.
Compared with other options
Typical differences between HABOILER equipment and a general-market alternative.
| Feature | HABOILER | General market |
|---|---|---|
| Manufacturing & inspection | Own factory, Class-A licence, third-party inspection | Trading company / outsourced production |
| Efficiency on site | Optimised combustion, low excess air, tested at commissioning | Nameplate figure only |
| Documentation | Drawings, material certificates, O&M manual | Limited or on request |
| After-sales | Spare parts and engineer support, remote diagnosis | Varies, often no local stock |
| Customisation | Fuel, pressure, voltage and layout adapted | Fixed catalogue models |
Further reading
sp_faq_h
sp_faq1_q
sp_faq1_a
sp_faq2_q
sp_faq2_a
sp_faq3_q
sp_faq3_a
sp_form_h
sp_form_p